go to text

LED lighting

Proposal for energy saving

Significant reduction in electricity charges!

Replacing fluorescent lights with LEDs can reduce your electricity bill by about 60%.
The earlier the introduction, the greater the saving effect.

Work efficiency is improved by the LED with dimming function!

The brightness and color of the CV21 LED can be adjusted according to the work environment.
"The introduction of LEDs has made warehouse cargo handling and clerical work easier."
customer feedback
I have received.

LED with motion sensor saves even more!

It detects a person and turns on automatically, and turns off automatically when there are no more people.
Recommended for corridors, etc.

Save a lot of initial costs!

Since it can be attached to existing fluorescent light fixtures with simple electrical work, installation costs can be reduced.can suppress
can.In addition, by utilizing installment sales, leasing, etc.,A lot of initial investment amountsave money.
Please contact us by all means.
LED and fluorescent cost simulation

Product Introduction

Benefits of introducing LED lighting

 Power consumption can be significantly reduced
 In general, the power consumption of LED lighting is reduced by 40 to 60% compared to fluorescent lighting.This also contributes greatly to the reduction of CO2 and plays a major role in preventing global warming.
fulfill.

 Eco-friendly lighting that does not use mercury
 Since LED lighting does not use the mercury contained in fluorescent lamps, it can be said to be environmentally friendly lighting.Also, because the arc tube is polycarbonate,
Even if it breaks, the glass will not scatter.

 Long life of 40,000 hours
 The expected life of fluorescent lamps is said to be 6,000 to 12,000 hours, but LED lighting
The expected life of the light source is 4 hours, which is much longer.This greatly reduces the frequency of lighting replacement.

 Less fever
 LED lighting is a light source that does not generate much heat, and compared to lighting such as fluorescent lamps, it can be expected to suppress the rise in indoor temperature and improve the efficiency of air conditioning.

 There is little ultraviolet light
 Since the light from LED lighting contains less ultraviolet rays that cause sunburn, it is less likely to fade or deteriorate even when irradiated to works of art, and it is also possible to prevent insects that are attracted to the ultraviolet rays from flying in.

 No ballast required
 Since LED lighting uses a power supply dedicated to LEDs, a ballast for fluorescent lamps is not required to light the LEDs. In addition, ballasts that have exceeded their lifespan may increase power consumption or cause an accident.

Features of straight tube LED lighting / CVL series

 Industry-leading high efficiency! Power consumption14.8w, Bright enough
 If you replace the 40-inch fluorescent lamp (40W) with our LED (14.8W),About 60%reduce power usage.Brightness equivalent to a 40-inch fluorescent lamp2,149lm(Lumen).

 The initial cost can be reducedNo need to replace equipmentType
 Since the CVL series is a G13 base type, it can be attached to the fluorescent lamp equipment you are using with simple construction. (If the device is very painful, it may not be possible to install it.)

Long life40,000 hours(Expected life of light source), and more secureProduct warranty 3 years
 It lasts about 10,000 times longer than the expected life of fluorescent lamps (about 4 hours). The frequency of lamp replacement is greatly reduced. For general usage time, the payback period is less than 3 years. You can rest assured with a 3-year product warranty.
 
Why don't you save electricity and power cost for eco2 with LED lighting of CVL series?

Reliable quality control system

Quality Control Manager Tsuneki Kitamori
All LED lighting "CLV series" are inspected at the CV21 Kyoto factory. A serial number can be printed on the accepted products for tracking management.
We guarantee the quality for 3 years, so you can use it with confidence.
Inspection contents
Inspection report and inspection scenery

Characteristic lineup of CVL series

Straight tube type LED popular type

LED lamps can be installed using existing lighting fixtures.
With a G13 base and a slim shape with a tube diameter of 30 mm, not only general fluorescent lamps (FL, FLR) but also Hf fluorescent lamps can be replaced with LEDs without changing the equipment you are using.
*When installing this LED lamp on an existing fixture, it is necessary to investigate the condition of the existing fixture in advance.
 Power consumption can be significantly reduced by about 40% of fluorescent lamps.
Model
Input voltage
(V)
Power
(W)
Total luminous flux
(Lm)
Luminous efficiency
(Lm / W)
Color temperature
(K)
Color rendering
(Ra)
life
(time)
CVL20T110
20 type
Equivalent
AC90~
 240
9.6
1,092
114
5,000
82.0
40,000
CVL40T120
40 type
Equivalent
AC90~
  240
17.8
2,136
120
5,000
82.0
40,000
CVL40
T45A50
40 type
Equivalent
AC90~
  240
14.8
2,149
145
5,000
83.7
40,000

Straight tube type LED 3-stage dimming type

 Even after replacement according to needs
  You can dim the light on the spot.
For example, you can reduce the brightness near the window to save power, and increase the brightness in a room without windows. By switching the switch according to the needs of the place, you can adjust the light in 3 steps on the spot.
Model
input
Voltage
(V)
Power
(W)
Total luminous flux
(Lm)
Luminous efficiency
(Lm / W)
Color temperature
(K)
Color rendering
(Ra)
life
(time)
Dimming
(※ 1)
CVL40
T145S3
Equivalent to 40 type
AC90
~240
18.8
2,632
140
5,000
82.0
40,000
H
14.8
2,146
145
M
11.8
1,711
L
CVL40
T175S3
Equivalent to 40 type
AC90
~240
15.5
2,635
170
5,000
82.0
40,000
H
12.3
2,152
175
M
9.8
1,722
L
CVL110
T145S3
110Equivalent to shape
AC90
~240
49.0
6,860
140
5,000
82.0
40,000
H
39.0
5,655
145
M
29.0
4,205
L
*1 H: High illuminance mode, M: Standard lighting mode, L: Low power consumption lighting mode

Straight tube type LED color temperature / luminous flux switching type

 Offices and stores will change.
  The color tone and light intensity of the lamp can be adjusted freely!
If you use the dedicated remote control, you can adjust the color tone of the lamp from daylight color to light bulb color according to your preference, and you can freely switch the light intensity (total luminous flux) between 2,700 lm and 550 lm.
*Remote control is sold separately.
 If you set your channel
  You can adjust multiple books at once.
If you use the channel setting function of the dedicated remote controller, you can divide multiple straight tube LEDs into up to 4 groups and register them in groups, and you can adjust the color tone and light intensity as a whole or in groups.
Model
Input voltage
(V)
Power
(W)
Total luminous flux
(Lm)
Luminous efficiency
(Lm / W)
Color temperature
(K)
life
(time)
CVL40TUSP
40 type
Equivalent
AC90~
  240
22.0
2,700
122
2,700 to 6,500
40,000
19.5
2,383
122
2,700 to 6,500
17.0
2,077
122
2,700 to 6,500
14.5
1,772
122
2,700 to 6,500
12.0
1,466
122
2,700 to 6,500
9.5
1,160
122
2,700 to 6,500
7.0
855
122
2,700 to 6,500
4.5
550
122
2,700 to 6,500
*2: The total luminous flux is a guide. It depends on the color temperature.

Straight tube type LED with motion sensor

 A sensor detects human movement and
   Turns on and off automatically.
When the motion sensor built into the LED lamp detects a person within the sensing range (height 3m, diameter 5m), the lamp automatically lights up. Also, if there is no person within the sensing range after the set lighting time has passed, the lamp will automatically turn off.
 With the changeover switch, you can select lighting time and complete extinguishing or 10% luminous flux
Straight tube type LED motion sensor type / installation example
Corridor
backyard
Bathroom
Model
Input voltage
(V)
Power
(W)
Total luminous flux
(Lm)
Luminous efficiency
(Lm / W)
Color temperature
(K)
Color rendering
(Ra)
life
(time)
CVL20
T100J4
20 type
Equivalent
AC90~
 240
10.0
1,000
100
5,000
82.0
40,000
CVL40
T120J4
40 type
Equivalent
AC90~
 240
17.8
2,136
120
5,000
82.0
40,000

LED base light GB1 series

Slim & thin design
Slim and industry-leading thinness (38mm)
It is the base light of the design.
Although the light source, power supply, and mounting part are integrated, the weight of the main unit is kept to 1 kg or less (GB1 series), making it easy to use.
I can handle it.

 Low frequency noise
Realizes low noise and high efficiency. All models of the GB1 series have cleared the CISPR15 standard, so they can be used safely in data centers, etc.

 Long life 60,000 hours
The long-life design makes it ideal for places where maintenance is difficult.
* Expected life of the light source when the average ambient temperature is 30 ° C


 Easy to install
A slide cover mechanism is used for the mounting part.The main body can be held with one hand and can be installed by one person.
*Electrician qualification is required.
GB-1 series / outline drawing
Model
Input voltage
(V)
Power
(W)
Total luminous flux
(Lm)
Luminous efficiency
(Lm / W)
Color
temperature
(K)
Color rendering
(Ra)
life
(time)
GB100258
NSA
40 type
Equivalent to 1 lamp
AC100
~242
18.8
2,150
114
5,000
85.0
60,000
GB101756
NSA
40 type
Equivalent to 2 lamp
AC100
~242
39.0
4,000
102
5,000
85.0
60,000
GB102158
NSA
40 type
Equivalent to 2 lamp
AC100
~242
40.0
5,500
137
5,000
85.0
60,000
GB101358
NSA
40 type
Equivalent to 2 lamp
AC100
~242
34.2
5,250
153
5,000
85.0
60,000
GB110258
NSA
110 type
Equivalent to 1 lamp
AC100
~242
40.3
5,400
134
5,000
85.0
60,000
GB110758
NSA
110 type
Equivalent to 2 lamp
AC100
~242
68.4
10,550
154
5,000
85.0
60,000
*LED base light GB-1 series is a product of Sanken Electric Co., Ltd.

Compliant standards / precautions

Compliant standard

Precautions when installing LEDs

  1. Do not connect to a three-phase power supply.
  2. In factories with large inductive loads, it is recommended to install a noise filter with a power supply to prevent malfunction of the LED straight tube.
  3. Power consumption varies slightly depending on the usage environment.In addition, brightness,         There is some variation in light color.
  4. Expected life means the expected life in an environment with an average ambient temperature of 30 ° C.
  5. Specifications are subject to change without notice due to improvements. Please note.
  6. In addition to the products listed in this catalog, we also handle various LED lighting fixtures.Please contact the person in charge for details.

Precautions when connecting to existing fluorescent lighting fixtures

1.For glow type, be sure to remove the glow before use.
2.Existing fixtures have built-in ballasts to smoothen the start-up of fluorescent tubes.
3.Ballasts have a lifespan, and generally one that has been used for more than 30,000 hours
  Performance deteriorates with deterioration.may decrease.
4.Ballasts themselves also consume power, and old ballasts can lead to fire.
  Because there isDisconnect the ballast circuit before use.
5.Please refer to the diagram below for disconnecting the ballast circuit.
○ ── ○ ・ ・ ・ Wiring connection work × ・ ・ ・ New line construction
Note) Power to the LED lamp is supplied from both ends of the socket.

LED lighting straight tube lamp, base light general catalog download

LED lighting installation example

20244
Sun
Mon
Tue
Wed
Thu
Fri
Sat
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
Clean Venture 21 Corporation

612-8445
Kyoto City, Fushimi-ku, Takeda Jobodain-cho 41

TEL.075-612-2100
FAX: 075-612-2177
Back to TOP